Customer Solution Portal

Submit a ticket My Tickets
Welcome
Login  Sign up

Error Code - 5 - Temp Over

Definition: Ambient or internal temperature is too high


Possible Causes: 

  1. Ambient temperature outside the inverter is too high
  2. Fan is blocked
  3. Convection airflow is insufficient due to improper installation

Recommended Solutions: 

  1. Confirm that external ambient temperature is within the specified range of operating temperature.
  2. Check whether air inlet is blocked
  3. Check whether fan is blocked
  4. Check whether the location of installation is appropriate or not
  5. Observe for 30 minutes and see whether the alarm will be eliminated automatically
  6. Contact after-sales service personnel

Did you find it helpful? Yes No

Send feedback
Sorry we couldn't be helpful. Help us improve this article with your feedback.