Customer Solution Portal

Submit a ticket My Tickets
Welcome
Login  Sign up

Error Code 120-127 - String 1-8 Reversed

Possible CauseSuggestions
Cause ID 1: Major

The PV string is reversely connected.
Check whether the PV string is reversely connected to the SUN2000. If yes, wait until the solar irradiance declines at night and the PV string current reduces to below 0.5 A. Then, turn off the two DC switches and correct the PV string connection.


Cause ID 2: Warning

Only a few PV modules are connected in series to the PV string, and therefore the end voltage is lower than that of other PV strings.


Check whether the number of PV modules connected in series to the SUN2000 is small. If yes, increase the number.



Did you find it helpful? Yes No

Send feedback
Sorry we couldn't be helpful. Help us improve this article with your feedback.