Customer Solution Portal

Submit a ticket My Tickets
Welcome
Login  Sign up

Fault - 1 - No info

Cause-

  • Input voltage low/missing
  • Polarity reversed
  • Main Board Damaged


Solution-

  • Test- DC switch OFF
  • Check PV connections
  • Check polarity
  • Check voltage >120V Single, >350V three
  • Test- DC Switch ON
  • Check voltage >120V Single, >350V three
  • If DC voltage is “ 0” replace inverter

Did you find it helpful? Yes No

Send feedback